Sma log software
Canada English. Greater China Chinese. Czech Czech. Finnland Finish. France French. Greece Greek. Hungary Hungarian. India English. Italy Italian. Ireland English. Japan Japanese. Israel Hebrew. Korea Korean. Luxembourg French. Malaysia Malaysian.
Mexico Spanish. For greater flexibility, there will be three different communication profiles to choose from. These profiles ca be activated in the Sunny Portal.
Expanding the grid management services Output of cos phi via Modbus Values for cos phi can now be output via Modbus. This includes both the obtained default values and the currently measured cos phi value at the point of interconnection.
For this, a meter at the point of interconnection is imperative. Active power setpoints via external digital inputs Default active power values can now also be processed via external digital inputs for example, via the Wago Bundle or Moxa ioLogic.
Update February Extended support of connected devices Threshold based toggle of digital outputs From now on it is possible to toggle digital outputs based on active and reactive power level of the pv plant. If there is an energy excess a digital signal can be sent to an electric load to switch on for example a heating rod or a heat pump.
Hereby irreversibilities by external power curtailment setpoints can be reduced and the produced energy can be used more efficient. Hereby manually created modbus profiles can be added to connect for example the weather station PVMet from Rainwise. Also connection of sensors to display a filling level level in percent value is possible by using the new Modbus device type.
This measured data is currently only available locally on the Data Manager M. The other way round open loop and close loop control of the inverters is also possible now. The fix added Modbus profiles guarantee a reliable promt of the requested measurement data. Extension of grid management services Support of reactive power setpoints via external digital inputs Now reactive power setpoints via external digital inputs e. Hereby it is possible to fullfill the requirements of the grid operstors more flexible.
The devices connected to the Inverter Manager are aggregated and displayed as one device. This reduces the required data volume for systems that are connected via the mobile network to the Sunny Portal powered by ennexOS. Advanced support for connected devices Connection of inverters from other manufacturers Implementing the Modbus Sunspec interface means that inverters from other manufacturers can now be monitored and managed using the EDMM and visualized in Sunny Portal.
Soon also available directly from SMA. SMA order number: Up to 50 devices or a maximum system size of 2. Available features as of release 1. Subject to change. I connected the Data Manager correctly. Depending on the web browser, the entry may be interpreted as a search entry.
I reset the Data Manager to the default settings. Why do I get an error message regarding an invalid certificate when I want to access the Data Manager with the web browser?
In order to save the self-signed certificate of the Data Manager in the web browser, it must initially be accepted as trustworthy in the web browser.
After the Data Manager has been reset to the default settings, the web browser interprets this certificate as outdated or invalid. Delete the old certificate in the security settings of your web browser. Reconnect to the Data Manager and accept the newly offered certificate.
A list of all interfaces with IP address, physical address and type is displayed. The physical address indicates the associated IP address. Why are no data displayed on the user interface of the Data Manager?
I reset the password and administrator account of the Data Manager. Do I have to go through the entire installation assistant process and reenter all data when I log in the next time? Assign the user name and password and then stop the installation assistant.
The original PV system data are still there and are adopted automatically. Can several Data Managers be used in one system to map system sections, for example? This is not possible. However, system sections can be created and visualized in Sunny Portal powered by ennexOS. I want to change the data transfer rate of the SMA Energy Meter from ms to ms to obtain a higher control dynamics. Can the Data Manager handle this? A few RS devices are currently not yet supported by the Data Manager:.
Schedule them to run at preset frequencies such as daily, weekly or monthly to make sure the appropriate individuals receive information they need. Organization and power management Save time and money with a variety of functions that improve IT operational efficiency. Take advantage of wake on LAN capabilities to assist with patching and software distribution during off-work hours.
Create, enforce and report on power policies and shut down non-essential systems during off-work hours for dramatic energy cost savings. Resources Datasheet. Free inventory tool Windows hardware and software inventory.